Liquid Cooling Solutions

Liquid Cooling Pump BLDC Motor Driver ICs

Smart pump solutions for CDUs and direct liquid cooling loops. Precise control, superior efficiency. inergy keeps AI data centers cool, efficient, and always on.

CDU Pump Driver 12V / 24V / 48V 3-Phase FOC Always-On Reliability
LIQUID COOLING
Smart Pumps · Precise Control · Ultimate Efficiency
CDU Control
Direct Loop
Redundancy
Flow Control
inergy-Drive™ · 3-Phase FOC Pump Control

Smart Pumps. Precise Control. Ultimate Efficiency.

Liquid cooling is the critical frontier for AI data centers pushing thermal density limits. inergy's pump driver ICs deliver the reliability, control precision, and efficiency needed for 24/7 always-on cooling loops in CDUs and rack-level liquid cooling.

  • FOC vector control — smooth, quiet, vibration-minimized pump operation
  • 48V CDU support — iU6398 HV-Buck eliminates thermal limits of external step-down
  • Constant flow/power control — maintains reliable cooling under varying back pressure
  • Auto-optimize under load variation — self-learning efficiency across all conditions
  • Startup in zero/forward/reverse flow — robust in all liquid conditions
  • Compact QFN 4×4 — fits 40mm pump PCB form factor for small-form pump designs
View IC Selection →
Liquid Cooling Applications

AI Datacenter Cooling Architecture

From rack-level CDUs to direct-to-chip liquid cooling, inergy pump ICs address every layer of modern AI datacenter thermal management.

Facility Level

CDU — Coolant Distribution Unit

Central liquid distribution systems delivering coolant to multiple racks. Requires high-reliability 24/7 pump operation with flow monitoring and redundancy support. 48V pump motor preferred.

iU6398 48VFOC Constant Flow
Rack Level

Rear-Door Heat Exchanger Pump

Rack-integrated liquid cooling loop pumps circulating coolant through rear-door heat exchangers. 12V or 48V pump with precise speed control for thermal efficiency.

iU6395 12ViU6391 12/24ViU6398 48V
Component Level

Direct Liquid Cooling (DLC) Pump

Small form-factor pumps for direct-to-chip or direct-to-board liquid cooling of GPUs, CPUs, and HBM memory. Low vibration, low noise, compact PCBA design.

iU6291 12ViU6395 12ViU6391 24V
IC Lineup

Cooling Fan & Pump Driver ICs

Four product families covering all voltage tiers and motor configurations for AI server fans and liquid cooling pumps — now including the new iU6395 N/N FOC controller recommended for high-current 12V designs.

48V · 3-Phase FOC · HV Buck

iU6398

HV-Buck integrated FOC driver for 48V server fans. Max 160V N/N pre-driver, internal temperature sensor. Eliminates thermal limits of external step-down loops.

20V–80V (120V max)N/N Pre-driverQFN 4×4-32L
Details →
12V · 3-Phase FOC · N/N New ★ Recommended

iU6395

Newest 12V-class 3-phase FOC controller — recommended successor to iU6391. N/N MOS pre-driver, dual integrated current-sense amplifiers and op-amps, dedicated 8V gate-drive rail, internal + external thermal sensor.

5V–18VN/N Pre-driverDual Current AmpQFN 4×4-28L
Details →
12V/24V · 3-Phase FOC · N/P

iU6391

Three-phase sensorless FOC driver with built-in 5V LDO and 40V N/P pre-driver. Supports constant power, constant current, and adjustable lead angle modes. Covers the wider 7–32V (12V/24V) range.

7V–32VN/P Pre-driverQFN 4×4-28L
Details →
12V/24V/48V · Single-Phase

iU6291

Single-phase sine-like waveform driver. Adjustable lead angle (positive/negative/zero-crossing). Waveform control to reduce commutation noise and vibration. 40,000 RPM @ 12V.

7V–32VN/P Pre-driverQFN 4×4-20L
Details →
IC Selection Guide

Pump Driver IC Selection

PartVoltagePhaseKey FeaturePump ApplicationStatus
iU639820V–80V (120V max)3-Phase FOC HV-Buck integrated, 160V N/N pre-driver, internal OTP 48V CDU Pump, Data Center Primary Loop Recommended
iU63955V–18V3-Phase FOC N/N pre-driver, dual current-sense amps, 8V gate-drive rail, int. + ext. OTP 12V High-Current Rack / DLC Pump New ★ Recommended
iU63917V–32V3-Phase FOC 5V LDO, 40V N/P pre-driver, constant power/current, Hall optional 12V/24V Rack Pump, Rear-Door Loop Active
iU62917V–32VSingle-Phase Waveform control, lead angle ±, constant power, low noise 12V/24V Direct Cooling Small Pump Active
Performance Advantages

Why inergy-Drive™ for Liquid Cooling?

Ultra-Low Vibration

FOC sinusoidal current delivery eliminates torque ripple — critical for rack-level vibration budgets in high-density AI facilities.

Constant Flow Control

Constant power/current modes maintain consistent coolant flow regardless of back pressure changes from cold plates or cooling load variation.

All-Condition Startup

Supports zero-flow, forward-flow, and reverse-flow startup. Critical for systems where pumps may start under residual flow conditions.

FG Speed Monitoring

Programmable FG output with adjustable frequency multiplier. Integrates directly with BMC/IPMI for pump health monitoring and control.

Keep AI infrastructure cool 24/7

Request Liquid Cooling Pump Reference Design

Get application-specific schematics, BOM, Gerber files, and firmware for your pump motor project. FAE engineers will customize for your CDU or rack cooling architecture.