inergy Technology inergy PC & Server Power

Power MOSFETs for PC and AI-server power

From the 800VDC rack bus to the Vcore buck on the motherboard, every power stage switches through MOSFETs. inergy covers the chain with 650V – 1200V SiC for PFC and HVDC, 60V – 100V SGT for 48V conversion and battery backup, and 30V devices down to 0.6 mΩ for chargers and VRMs.

Pick the socket. Get the shortlist. Open any part in the full selection guide.

AI SERVER RACK AC277V PSU PFC LLC SR HOTSWAP 48VBUS 48→12VIBC 12VPOL GPU/ CPU 800VDC · SST / SSCB BBU FANS PC / NOTEBOOK AC230V ATX PSU PFC LLC SR 12V USB-CADPT CHARGER AC/RBFET BUCKBOOST BATFET VSYS NB PACK VRMVcoreVNN5V · 3.3V HS ▪ LSDUAL-N CPU/ GPU SELECT A SOCKET 20V – 1200V · Si / SiC
Two power chains, one portfolio. Hover a block for the recommendation; click it to pick that stage.
Start with the power stage. Where does the MOSFET sit?
Pick the platform, then the socket. Voltage class follows the worst-case stress at that socket, not the nominal rail.
Pick a socket to see the recommended voltage class and the inergy devices that fit.

Part numbers with a dashed underline open that device in the selection guide, with the full parameter sheet and datasheet download.

PC & server power portfolio

Every device the PC and AI-server design guide calls out, in one sortable table. Parts already in the selection guide carry the guide's released specifications and link straight to it; new SiC and upcoming parts show preliminary values — ask us for data.

Tap a row for the full specs, where the part is used, and the guide link.

Part number Type VDS Rds(on) max ID @25°C Qg Package Status Add to shortlist

Specifications for linked parts are from inergy MOSFET Selection Guide v2026.Q3.0. Rds(on) is the maximum at VGS = 10V unless marked @4.5V (logic-level parts); dual and N+P parts show N / P or Q1 / Q2 values. "New" parts are not yet in the online guide: SiC Rds(on) marked * is the nominal class from the part code, and HVDC values are typical — confirm against the datasheet.

Full MOSFET selection guide — 260 parts

What the portfolio covers

20 – 1200V

One supplier, whole chain

Small-signal SOT-23 for cell balancing through 1200V SiC for 800VDC distribution — one qualification, one supply relationship.

0.6 mΩ

Low-side conduction

30V PDFN5x6 down to 0.6 mΩ for high-current Vcore and charger low-side positions, where Rds(on) sets the thermal budget.

650 / 750 / 1200V

SiC for the front end

TOLL SiC MOSFETs for totem-pole PFC and LLC primaries, and 750V / 1200V devices for HVDC racks, SST and solid-state breakers.

Where our silicon sits

Each card is one stage of the power chain. Pick a socket to filter the portfolio to the devices that fit it.

Notebook charger and 48V reference tables

Sizing shortcuts from the application team. Every part number opens in the selection guide.

Adapter → VSYS: HPB charger ACFET / RBFET

Adapter powerACFETRBFET

48 → 12V HSC switch stress

DeviceVoltage stressCurrent stressinergy class

With N1 = N2. The Lr–Cr resonance gives zero-current turn-on, so conduction loss dominates — choose by Rds(on).

Charger switching MOSFETs by charge current

ChargerConditionHigh-sideLow-side

Dual parts (iM1635, iM1625) carry both switches in one package. BATFET: iM1804 for 0–8A discharge or adapters below 140W; iM1826 for 8–15A or adapters above 170W.

Design-in path

Three steps, in the order they usually happen with ODMs and brand owners.

First

Request samples

Evaluation samples shipped against your platform and socket — PSU, IBC, BBU, charger or VRM.

On the bench

Efficiency validation

FAE support for efficiency and thermal testing on your board, and schematic review.

At ramp

Volume agreement

Volume pricing and supply security aligned to your platform launch. Taiwan-based design and support.

Tell us about your power stage

Send the topology, input and output rails, current per phase and switching frequency. We will come back with a device shortlist and sample availability.